2036-25-C2FLF vs 2036-25-C2 vs 2036-25-C3

 
PartNumber2036-25-C2FLF2036-25-C22036-25-C3
DescriptionGas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBEGas Discharge Tubes / Gas Plasma Arrestors Sparkover100V/s 250V Miniature 3 PoleGas Discharge Tubes / Gas Plasma Arrestors Sparkover100V/s 250V Miniature 3 Pole
ManufacturerBournsBourns Inc.Bourns Inc.
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tube Arresters (GDT)Gas Discharge Tube Arresters (GDT)
Series2036
Peak Pulse Current20 kA--
DC Sparkover250 V--
Number of Electrodes3 Electrode--
Termination StyleRadial--
Failsafe Protection Y/NFailsafe Protected--
Diameter5 mm--
Length7.5 mm--
Minimum Operating Temperature- 55 C--
Maximum Operating Temperature+ 105 C--
TechnologyGas Discharge Tubes--
TypeMiniature 3-Pole Gas Discharge Tube--
BrandBourns--
Mounting StyleThrough Hole--
Insulation Resistance10 GOhms--
Product TypeGDTs - Gas Discharge Tubes / Surge Arresters--
SubcategoryGDTs - Gas Discharge Tubes--
Packaging-TrayTray
Number of Poles-33
Package Case-Axial Cylinder, 3 Lead (Radial Bend)Axial Cylinder, 3 Lead (Radial Bend)
Mounting Type-Through HoleThrough Hole
Tolerance-±20%±20%
Voltage DC Spark Over Nom-250V250V
Impulse Discharge Current 8 20μs-10000A (10kA)10000A (10kA)
Fail Short-NoNo