2027-47-C vs 2027-47-C10LF vs 2027-47-CLF

 
PartNumber2027-47-C2027-47-C10LF2027-47-CLF
DescriptionGas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 470V 2 PoleGas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBEGas Discharge Tubes / Gas Plasma Arrestors GAS DISCHARGE TUBE 2POLE 470VOLT
ManufacturerBournsBournsBourns Inc.
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tube Arresters (GDT)
RoHSNY-
Series202720272027
Peak Pulse Current25 kA25 kA-
DC Sparkover470 V470 V-
Number of Electrodes2 Electrode2 Electrode-
Termination StyleAxialRadial-
Failsafe Protection Y/NFailsafe Not ProtectedFailsafe Not Protected-
Diameter8 mm8 mm-
Length6 mm6 mm-
Minimum Operating Temperature- 55 C- 55 C-
Maximum Operating Temperature+ 125 C+ 125 C-
TechnologyGas Discharge TubesGas Discharge Tubes-
Type2-Pole Gas Discharge Tube2-Pole Gas Discharge Tube-
BrandBournsBourns-
Mounting StyleThrough HoleThrough Hole-
Insulation Resistance10 GOhms10 GOhms-
Product TypeGDTs - Gas Discharge Tubes / Surge ArrestersGDTs - Gas Discharge Tubes / Surge Arresters-
Factory Pack Quantity100100-
SubcategoryGDTs - Gas Discharge TubesGDTs - Gas Discharge Tubes-
Unit Weight0.056438 oz0.056438 oz-
Packaging--Bulk
Number of Poles--2
Package Case--Axial Cylinder
Mounting Type--Through Hole
Tolerance--±15%
Voltage DC Spark Over Nom--470V
Impulse Discharge Current 8 20μs--10000A (10kA)
Fail Short--No